42 AIEW Member Electrical Product Catalogue Issue 21 RCCB Incomer Consumer Units RCCB Rating Total MCB ways List No. Enclosure Size 63A 30mA 2 502/363B - 80A 30mA 4 504/383B 6M 80A 30mA 7 507/383B 9M Split Load Consumer Units MS Rating Total Ways Main Switch Ways 63A 30mA RCCB Ways List No. Enclosure Size 100A 8 4 4 508/2483B 12M 100A 11 5 6 511/2583B 15M 100A 11 6 5 511/2683B 15M 100A 11 7 4 511/2783B 15M 100A 16 7 9 516/2783B 20M 100A 16 8 8 516/2883B 20M 100A 16 9 7 516/2983B 20M RCBOs can be included for final circuit positions not protected by resident RCCBs Starbreaker Consumer Units Rating Type B Type C 6A 61/B06 61/C06 10A 61/B10 61/C10 16A 61/B16 61/C16 20A 61/B20 61/C20 32A 61/B32 61/C32 40A 61/B40 61/C40 50A 61/B50 61/C50 MCBs Enclosure size Pattress List No. Intumescent List No. North/South Entry 6M MNSPE6584/1NR CR0706FS 9M MNSPE6584/2NR CR1009FS 12M MNSPE6584/3NR CR1312FS 15M MNSPE6584/4NR CR1615FS 20M MNSPE6584/5NR CR2120FS Main Tails Gland List No. 32mm Cable Gland MTCG32 5 x 32mm flush fit Cable Glands CRTG32 Cable Membrane Entry Kits 7 x 20mm plus 3 x 32mm CRCE1 10 x 20mm CRCE2 Way Blanks Non combustible blank 543 Insulated MCB profile blank CSB1 Accessories All metal consumer unit pattresses and Intumescent strips • Cable pattresses allow surface cable entry through consumer unit rear knockouts • Intumescent strips are suitable for use within any like sized consumer unit Main Switch Consumer Units MS Rating Total MCB or RCBO ways List No. Enclosure Size 63A 2 502/26B - 100A 4 504/2B 6M 100A 7 507/2B 9M 100A 10 510/2B 12M 100A 13 513/2B 15M 100A 18 518/2B 20M with Surge Protection Device (T2) 100A 2 502/2BS - 100A 5 505/2BS 9M 100A 8 508/2BS 12M 100A 11 511/2BS 15M 100A 16 5162BS 20M Dual RCCB High Integrity Consumer Units MS Rating Total Ways Main Switch Ways 80A 30mA RCCB Ways 80A 30mA RCCB Ways List No. Enclosure Size 100A 9 1 4 4 509/218484B 15M 100A 9 3 3 3 509/238383B 15M 100A 14 3 6 5 514/238685B 20M 100A 14 4 5 5 513/248585B 20M 100A 14 6 4 4 513/268484B 20M with Surge Protection Device (T2) RCBOs can be included for final circuit positions not protected by resident RCCBs 100A 7 1 3 3 507/216363BS 15M 100A 12 4 4 4 512/248484BS 20M 100A 12 2 5 5 512/228585BS 20M Rating Type B Type C 6A 61/BM0630 61/CM0630 10A 61/BM1030 61/CM1030 16A 61/BM1630 61/CM1630 20A 61/BM2030 61/CM2030 25A 61/BM2530 - 32A 61/BM3230 61/CM3230 40A 61/BM4030 61/CM4030 Miniature RCBOs (SP&swN, 30mA) AFDD/RCBOs Rating Type B Type C 6A 61/B0630AFD 61/C0630AFD 10A 61/B1030AFD 61/C1030AFD 13A 61/B1330AFD 61/C1330AFD 16A 61/B1630AFD 61/C1630AFD 20A 61/B2030AFD 61/C2030AFD 25A 61/B2530AFD 61/C2530AFD 32A 61/B3230AFD 61/C3230AFD 40A 61/B4030AFD 61/C4030AFD (SP&swN, 30mA) www.electrium.co.uk

RkJQdWJsaXNoZXIy MjQwMjM=